Franch, Monica
- Total activity 53
- Last activity
- Member since
- Following 0 users
- Followed by 0 users
- Votes 0
- Subscriptions 28
Articles
Recent activity by Franch, Monica-
Signals Inventa: How can I search a list of compounds in SAR analysis app?
Method 1 : Table Filter (available in Inventa 3.2 and above) Right-click on the SAR table Select the magnifying glass icon A search box will appear at the bottom of the screen Select the multili...
-
Spotfire analyst throws an error "Global and user services could not be initialized".
Keywords: Ports, Global Services, Spotfire crash, mscorlib Problem: Spotfire analyst crashes with the following error "Global and user services could not be initialized. The application will clos...
-
Why do I get the following error when updating Signals VitroVivo? “ Initialization failed. The application is not set up correctly. It will now terminate”
Keywords: Signals VitroVivo, Initialization failed, terminate, Spotfire crash, update Problem: After updating Signals VitroVivo, spotfire Analyst crashes with below error message: Error messag...
-
Where do I find the Signals VitroVivo Metastore API documentation?
Keywords: API, documentation, metastore, Signals VitroVivo, Signals Screening Details: Use Metastore base URL tailed with /swagger-ui.html to get to the Swagger interface. * please note this is...
-
Troubleshooting - How to enable DEBUG logging on TIBCO Spotfire Analyst
How to enable DEBUG logging on TIBCO Spotfire Analyst Keywords: logs, DEBUG, spotfire analyst, troubleshooting Details: This article lists the steps to enable DEBUG logging on the TIBCO Spo...
-
Can I use files from Spotfire library in Signals VitroVivo workflow?
Problem: Can I use files from Spotfire library in Signals VitroVivo workflow? Solution: From version 3.0 of Signals VitroVivo it is possible to connect Spotfire library with Signals VitroVivo thr...
-
Spotfire Analyst crashes installing Signals VitroVivo – Error message: The installation failed due to an unknown problem.
Problem: I get the following error message in Spotfire Analyst when trying to install Signals VitroVivo Error message: The installation failed due to an unknown problem. See details for more info...
-
Signals Inventa error: SAR analysis. Failed to get display entities. Authorization required.
When using SAR analysis app the following errors appear: - 'SAR analysis. Failed to get display entities. Authorization required.' - 'Failed to load ‘AdvancedModalView’ Response status code does no...
-
Supported Spotfire versions for Signals VitroVivo 3.1 / Signals Inventa 3.1 / Lead Discovery Premium 3.1 / Lead Discovery 8.5
For Signals Inventa 3.1, Signals VitroVivo 3.1, Lead Discovery Premium 3.1 and Lead Discovery 8.5 the supported Spotfire versions are 10.10 and 11.4.
-
Error in Spotfire analyst: “Could not load file or assembly 'netstandard"
Problem: Unable to open Spotfire analyst after deploying Lead Discovery ChemCharts. Spotfire Analyst gives below error message and terminates Spotfire. Error message: Global and user services...