Product: TIBCO Spotfire®
Error while executing the TIBCO Spotfire Server 'uiconfig' batch file from the 'spotfireconfigtool' folder: "Could not establish contact with the database: This driver is not configured for integrated authentication"
The configuration tool offers the most frequently used configuration options and generally, we run the configuration tool from a local/remote machine other than the Spotfire server machine.
The configuration tool may return the below error, while using integrated authentication method to connect to the Spotfire Server Database
====================
Could not establish contact with the database: This driver is not configured for integrated authentication. ClientConnectionId:92b21998-d87e-46cb-bcc3-2820e726d0a1
====================
Note: 1) We can verify the authentication method in the bootstrap.xml file e.g. jdbc:sqlserver://servername:1433;DatabaseName=spotfire_server;integratedSecurity=true
2) This article is not applicable for TIBCO Spotfire Server 10.3.9 version. Reference article for 10.3.9 - https://support.tibco.com/s/article/Error-while-launching-uiconfig-tool-in-spotfireconfigtool-folder-when-Spotfire-database-Microsoft-SQL-Server-setup-with-Integrated-Windows-authentication
To resolve the above reported error, copy the corresponding 'sqljdbc_auth.dll' file inside the 'spotfireconfigtool' folder NOT inside the '<Spotfireconfigtool>/lib' folder. Below is the screenshot for the reference: