Product: TIBCO Spotfire®
TIBCO Spotfire Automation job (send email) task may fail with error "The operation has timed out. at System.Net.Mail.SmtpClient.Send"
You may see the below error when executing a "send email" task through Automation services.. The below error can be found in the automation services log "<installation folder>\tsnm\10.X.0\nm\logs\Spotfire.Dxp.Worker.Host.Debug.xxxxxxxxxxxxxxxxxxxxxxxx.log"
-------------------------------------------------------------
Task 3 'Send Email' failed with: Failed to send email using SMTP server 'mail.xxxxx.com' from 'abc@xyz.com' to 'efg@lnm.com'. Reason: System.Net.Mail.SmtpException: The operation has timed out. at System.Net.Mail.SmtpClient.Send(MailMessage message) at Spotfire.Dxp.Automation.Tasks.Tasks.SendEmail.SendTheMail(TaskExecutionContext context, String smtpHost, String fromAddress, String messageBody, AttachmentsInfo attachmentsInfo)
-------------------------------------------------------------
These issues are environment specific and may be seen in cases when the SMTP server or the Automation server (node manager) is busy.
- Export the Automation services configuration using the "export-service-config" command.
https://docs.tibco.com/pub/spotfire_server/10.3.9/doc/html/TIB_sfire_server_tsas_admin_help/GUID-5462A06E-20CC-4F42-BCB8-0A66C8EC1C18.html
- The configuration is exported to "<installation folder>\10.X.0\tomcat\spotfire-bin\config\root" on the Spotfire Server machine.
- Edit "Spotfire.Dxp.Worker.Automation.config" file
The default SMTP send timeout in "Spotfire.Dxp.Worker.Automation.config" is 100
(<smtp port="25" useTls="false" timeoutSeconds="100">)
- Try increasing it to "200" seconds and check the behavior.. (In this example it is set to 200. This value can be tweaked as per the requirement.)
- Save the file and import the configuration back to the database using (import-service-config)
https://docs.tibco.com/pub/spotfire_server/10.3.9/doc/html/TIB_sfire_server_tsas_admin_help/GUID-6D37ADC8-824A-4FC6-9028-94A0CB0061B5.html
- "Navigate to Spotfire Servers Administration Page > "Nodes & Services", select the Automation Service and update it with new configuration
Comments
0 comments