Date Posted:
Product: TIBCO Spotfire®
Product: TIBCO Spotfire®
Problem:
Creating a TIBCO Spotfire Server bootstrap file fails with error "This driver is not configured for integrated authentication"
Solution:
Spotfire administrators may see the following error when trying to create a bootstrap file for the TIBCO Spotfire Server using the Microsoft SQL Server (MSSQL) JDBC driver with Integrated Authentication:
There was an error connecting to the Spotfire Server Database: This driver is not configured for integrated authentication.
To resolve this issue, ensure that:
- The file "sqljdbc4.jar" (and no other version of MSSQL JDBC Driver) is present in "<Server Installation Directory>\tomcat\spotfire-lib" folder.
- The file "sqljdbc_auth.dll" is present in "<Server Installation Directory>\tomcat\spotfire-lib" folder. For version 10.3.9, the file "mssql-jdbc_auth-8.2.2.x64.dll" needs to be present in "<Server Installation Directory>\tomcat\spotfire-lib".
Comments
0 comments
Article is closed for comments.