After Spotfire server upgrade, when Spotfire Administrator user logs in to Spotfire Server web admin console,they can only see "Home" and "Analytics" options and no other options are visible.
Check Spotfire Server's server.log file for the following errors:
-----------
ERROR 2018-09-26T07:29:04,380+0200 [sfadmin, #48, #274] server.security.RoleManagerImpl: Internal error when looking up administrator privileges for user 'sfadmin[2689a4a5-61a2-402b-a928-e8cb4ac6804e]' in the UserDirectory
...
...
Caused by: com.microsoft.sqlserver.jdbc.SQLServerException: Invalid object name 'GROUP_MEMBERS_VIEW'.
------------
------------
WARN 2018-09-26T08:54:25,567+0200 [monitoring@SPOTFIRESYSTEM, #54, #144] ws.userdir.UserDirectoryService: An exception was thrown in method 'getGroupsRecursive'.
com.spotfire.server.userdir.DirectoryException: Failed to load group membership associations from database
...
...
Caused by: com.microsoft.sqlserver.jdbc.SQLServerException: Invalid object name 'GROUP_MEMBERS_VIEW'.
-------------
These errors indicates that there is some issue with group membership in Spotfire Database which may be causing this issue. Verify the following points:
1. Check user permissions in Spotfire Server database of the user that was used to run Spotfire Server upgrade tool. Check if this user has proper permissions (for example: CREATE SESSION, CREATE TABLE, CREATE PROCEDURE, CREATE VIEW, QUERY REWRITE) on database views for which you are getting errors in logs.
2. Check if your Spotfire Server database is equipped with integrated security. If yes, make sure that you checked/selected this integrated security option while running Spotfire Server upgrade tool.
3. Check if Spotfire Server database views for which you are getting above errors in logs, have been created properly in the database by the upgrade tool. If not, you may need to create these database views in the database user again with the help of your DBA.
Comments
0 comments
Article is closed for comments.