Problem:
Error when trying to create Spectra Section in Enotebook: “Spectrum” section type error: Could not obtain “AxSPCPlot” control window handle - Performance setting enabled by default.
Solution:
This happens because the Data Execution Prevention is enabled by default in Windows, try the following workaround: Run a command prompt as administrator (type "cmd" on the Run window). From the start menu, select "All Programs", then "Accessories" and right-click on the "Command Prompt" shortcut and choose "Run As Administrator". From here you can use the following command to disable Data Execution Prevention (DEP) with the following command: bcdedit.exe /set {current} nx AlwaysOff Please restart the PC or the workaround wont be completed.