Product: TIBCO Spotfire®
Web Player Monitoring tab fails to launch.
Versions: 7.0.x
Web Player Monitoring tab fails to launch in a web browser, and if it is opened in Internet Explorer, it throws the following error:
"This content cannot be displayed in a frame".
The error "This content cannot be displayed in a frame" comes up if the component is blocked.
Resolution
* Open Internet Information Services (IIS) Manager.
* Browse to the Spotfire WebPlayer website and click on the SpotfireWeb application.
* In the "IIS" section, within the center pane, click on "HTTP Response Headers"
* In the "Actions" pane on the right, click "Add" and enter the following:
Name: X-Frame-Options
Value: SAMEORIGIN
* Click OK.
Note: If the X-Frame-Options parameter is present but with values either "DENY" or "ALLOW-FROM uri", change the value to "SAMEORIGIN".
Restart the Spotfire Web Player Application Pool (or restart IIS, if the Spotfire Web Player is the only site installed on the IIS instance), for the changes to take effect.
Reference
X-Frame-Options,
https://support.microsoft.com/en-us/kb/2694329
https://blogs.msdn.microsoft.com/ieinternals/2010/03/30/combating-clickjacking-with-x-frame-options/
Comments
0 comments
Article is closed for comments.