When using Revvity Signals Apps the following error appears:
'Warning message: Workflows folder preference is empty, only out of the box workflows will be available'
Keywords: Workflows, Signals VitroVivo, preference, warning, apps
Details:
To be able to share workflows across users, Signals VitroVivo requires that a library folder is configured on the server and the library folder path is defined in the corresponding Signals VitroVivo preference.
- Open TIBCO Spotfire® Analyst as an administrator.
- Go to Tools > Library Administration and create a new folder to store the Workflows for a given user group.
- Grant Browse+Access+Modify permissions to the folder for the group.
- Open Tools > Administration manager > Preferences. Set the Signals Apps > Settings > Protocol Library Folder preference to the path of the previously created folder (step 2).
-
Restart Spotfire Analyst
Note: When adding the library path do not include “Library/”, as all paths are defined relative to this folder.
Comments
0 comments
Article is closed for comments.