Signals Clinical: Can I change the configuration of Line Listing Review (LLR) in Signals Clinical 3.x after Study data exists?
Problem:My organization has a Signals Clinical tenant along with Line Listing Review (LLR), and we want to understand ramifications caused by changes to the configuration of Line Listing Review (L...
-
Spotfire Analyst: The Python Tools 'Install' button does not update to the latest version of the selected Python Package
Background: The Spotfire Analyst client application contains a dialog box to manage Python packages so that scripting in analysis files can use these Python functions. The dialog box is accessed ...
-
Spotfire: Manually updating the Action Log Database to v14 when separated from main Spotfire database
Description: In some Spotfire installations, the Action Log database may be located on a different server or use a different database management system than the main Spotfire database. In th...
-
Signals Line Listing Review: Sometimes the Review Status of all rows resets to New
Description: In some instances, users of Signals Line Listing Review (SLLR) may experience an unexpected reset of Review Status to "New", for all Lab values in their Clinical Study, losing previ...
-
Signals Line Listing Review: Importing a Study exported from another Spotfire environment may fail.
Background:A typical Line Listing Review (LLR) scenario with Spotfire and Medidata Rave is that the customer has a development environment and a production environment, and they have the same study...
-
Spotfire Server is unable to connect to its Oracle database, with error ORA-20001: Whitelist restriction
Details: Spotfire Server installation process includes creation of a bootstrap file, which identifies its database. If Oracle database is used, it may refuse to accept requests from your Spotfire...
-
Signals Clinical: The data connnection configuration page may report the connection configuration as 'not valid'.
Details: Signals Clinical has a configuration page where you define data connection to an external data source (types can be FTP or Medidata Rave). The external data source is provided by the cus...
-
Signals Clinical: Resolving "Unprocessable Entity" error during ECG domain mapping
Problem: When attempting to map the ECG domain in Signals Clinical, users may encounter an "Unprocessable Entity" error that prevents successful mapping. This issue appears to be related to ...
-
Rave Connector: Troubleshooting Clinical Cache refresh failure with Spotfire Server
Description: This article addresses a scenario where the Rave Connector's Clinical Cache database fails to receive new information from the external Medidata Rave system, resulting in outdate...
-
Spotfire Analyst: Information Designer tool fails to launch with error "Could not start Information Designer because the Information Services did not respond as expected."
Problem: The Information Designer tool in the Spotfire Analyst client fails to open with an error popup stating:"Could not start Information Designer because the Information Services did not respon...