We upgraded to Signals Inventa 3.2. We can not find the preference for Maximum Data Join Limit. Where can we configure this value?
Keywords: Maximum Data Join Limit, Signals Inventa, SIA, SDF, Signals Data factory
Details: Currently, the option to modify this preferences has been removed in order to optimize performance.
Administration Manager Signals Inventa 3.0
Administration Manager Signals Inventa 3.2
In Signals Inventa 3.2, there is no way to modify this setting in the client. The default is 100,000.
If you look at the Revvity Signals Inventa v3.2 User Guide, it mentions a ‘Search Maximum Join’ administrative system configuration setting in Signals Data Factory. This setting should only be modified after careful consideration with the Services team.
Signals Inventa 3.2 has optimized search settings and the max join size. Through thorough testing, it was found that 100,000 to be a value that gave a reliable performance. A value above 250,000 impacts performance.
***Please note that in SaaS this is not configurable.